• 84-position vial tray with optional vial chiller to 4 °C
  • Reduced footprint by 13 cm (5”) compared to the previous generation Atomx
  • Reduction of the amount of water transferred to the GC by as much as 60% over previous models, due to the improved Moisture Control System
  • Reduction of potential leak sources due to a precision machined valve manifold block, ensuring a reliable and robust system
  • Faster trap cooling time through dedicated ducting
  • Re-designed software that is intuitive, user-friendly, touchscreen compatible and USB driven to be fully compatible with Windows 10
  • Use of Helium or Nitrogen due to the ​​Electronic Mass Flow Controller (MFC). The MFC gives the ability to vary flow rates in different modes thus increasing sample throughput
  • Excellent desorption efficiency due to proprietary trapping material
  • Optional Guardian Foam Sensor and Eliminator for foaming sample types
  • Foam detection and prevention options, vial chilling and sparge vessel heater accessories all available​

Methods ​

  • USEPA 502.1, 502.2, 524.2, 524.3, 524.4, 503.1, 601, 602, 603, 624, 5030, 5035, 8010, 8015, 8020, 8021, 8030, 8240, 8260
  • ASTM and Standard Methods
  • Massachusetts VPH and GRO Methods​​

​Automation​​

​Sample Capacity:
​84-positions for 40 mL VOA vials.
​Vial Size:
​Nominal 40 mL capacity, single hole cap with PTFE-faced silicone septum, per EPA specifications; 3 3/4“ high without cap and septum; 1 1/16” OD; 24 mm ID cap for water sampling.
Sample Handli​ng
​Liquid Handling:
​Sample syringe (25 mL) dispenses variable volumes of water from 1 - 25 mL in 0.1 mL increments. 1/16” OD PEEK™ tubing for liquid transfer
​Sample Gas Pathway:
​Glass, PEEK™, SilcoNert® 2000 and PTFE for sample handling. 
​Cleaning:
​The entire liquid sample pathway can be rinsed using a combination of the methanol rinse and the high-temperature DI water rinse cleaning techniques. User defined rinse volume and number of rinses for the needle and glassware.
Gas H​​andling
​Electronic MFC:
​System is capable of controlling flow rates between 5-500 mL/min variable between each mode of operation.
​Pressure Monitoring:
​Ability to record purge and bake pressure for each sample.
​Gas Supply:
Ultra-high purity (99.999%) Helium or Nitrogen; Incoming Pressure: 65 - 100 psig, (100 psig max)
Standard ​​​Injection
​Standard Injection:
​Three standard injection systems utilizing 2-way dosing valves mounted on an internal valve manifold
​Capacity: 
​1, 2, 5, 10, and 20 µL increments.
​Consumption:
​1 µL per 1 µL injection
​Standard Vessels:
​Three 15 mL standard vessels, UV-protected and sealed under pressure for standard concentration integrity
Liquid Sa​​mples
includes drinking water and wastewater; Liquid samples containing up to 15 mm of sediment when measured from the bottom of an upright 40 mL vial
​Sample Glassware: 
​The system is capable of operation with 5-25 mL frit or fritless sparge vessels. Ships standard with 5 mL fritted glassware.
​Sample Dilutions:
​Programmable automatic aqueous sample dilutions of 1:100, 1:50, 1:25, 1:10, 1:5, 1:2
​Blanks:
​Automatic blanks can be pulled from the water reservoir and spiked with standard allowing all autosampler positions to be used for samples. 
​Cycle Time:
​Total Purge & Trap cycle time of 18 minutes, or less depending on the method.
Low-Level Solid Sam​​ples
includes all types of natural soils and sediments. Sampled: Direct purge in the vial per USEPA 5035 low-level soil methodology
​Sample Needle:
​A 3-stage needle allows for water and standards to be directly added to the vial where the solid sample will be purged.
​Vial Heater: 
​Variable heat control from ambient to 90 °C.
​Mixing:
​The solid sample can be mixed via a stir bar using three variable speeds.
High-Le​​vel Solid Samples
includes all types of soils and sediments. Sampled: Automated Methanol Extraction and subsequent dilution per USEPA 5035 high-level soil methodology
​Extraction:
​System is capable of fully automating the methanol extraction of high-concentration soil samples.
​Matrix Spike:
​The system is configured to allow a surrogate spike to be added directly to the solid sample when the methanol is added for the extraction.
​Extraction Dilutions:
​Programmable automatic dilutions of methanolic extract of 1:100 or 1:50 for 5 mL sample volumes
System Co​​ntrol
​Instrument Control:
​Atomx XYZ TekLink™ software in a Windows® 7 or greater environment. Via USB
​Method Scheduling
​All method types can be run from any position in the sample sequence. Up to three standards can be added to any user-specified position. Multiple runs can be made from the same vial (not recommended).
​System History:
​The system records a complete history of all sample, schedule and method information.
Servi​​​ce
​Electronic Leak Check:
​Ability to leak check the entire sample pathway of the system via the automated System Leak Check. Built-in diagnostics that, once a leak has been identified, the system will check independent sub-systems for leaks.
​Benchmark Test:
​The system has a mode that will allow for full electromechanical testing including; valving, heaters, vial handling systems, liquid delivery system, inputs and outputs.
​Diagnostics:
​The system offers independent control of all valves, vial handling mechanisms and syringe drive for troubleshooting.
General Sp​​ecifications
​Dimensions & Weight:
​Dimensions: 70.1 cm (27.6” W) X 58.42 cm (23” D) X 49.5 cm (19.5” H)
Unit weight: 43.1 kg (95 lbs
​Power Requirements: 
​100-120VAC (±10%), 50/60 Hz, 10.0A, 1150W; 220-240VAC (±10%), 50/60 Hz, 5.0A, 1150W
​Environmental Specs:
​Operating Temperature: 10°-30 °C; Storage Temperature: -20°-60 °C; Relative Humidity: 10%-90%
​Corrosion Resistance: 
​​The front cover and sample tray are corrosion resistant to waters with a pH range of 1-10.​

Windows® is a registered trademark of Microsoft®, ​PEEK™ is a trademark of Victrex PLC​​​​