Oils 7600

Dual Matrix Autosampler

Request a Quote

  • < Autosamplers
Oils 7600 Autosampler
Oils 7600 Autosampler
Illustration oil settling over time

Switch between oils and coolants testing on demand!

Oils testing laboratories are adding more sample types as their industry becomes more complex. The Oils 7600 Homogenizing Autosampler allows two sample matricies to be introduced to an ICP instrument from the same system. Boasting a dual port rinse station fed by two separate peristaltic pumps, it can change between oils and coolants testing on demand. With improved speed, mixing capability and sample drip capture, the Oils 7600 delivers robust analysis without compromise.​

  • Mix samples immediately prior to analysis for accurate results
  • Unique dual-matrix design for fast switching between sample types
  • Fast, smooth XYZ movement
  • Accurate positioning to ± 0.4 mm
  • No probe/stirrer alignment drift

​Why sam​​ple mixing?​​

Used oil samples typically contain particulate material that can settle in a sample tube prior to analysis; this can lead to generation of non‑representative data. The Oils 76​00 automation has been designed to resolve this problem. 

Prior to analytical measurement, a stirring paddle mounted next to the sample probe efficiently mixes each sample and, with the sample probe, is cleaned at the rinse station. Sample mixing is configurable, via the dashboard software, to meet the challenge of more viscous oil samples. ​

Accurate and fast​

Each sample is automatically homogenized prior to analysis. While the current sample is drawn, the next sample is being stirred to increase efficiency and save time​. Faster an​​d smoother XYZ movement saves up to 2 seconds per sample compared to previous generation oils automation. Analyze 2 samples per minute with the ASXPRESS PLUS rapid sample introduction for ASTM 5185 and ASTM 6130 testing.​

Maintain sample integrity

An integrated drip cup travels with the sample probe and stirring paddle to capture any sample droplets, eliminating cross contamination while moving over the sample tubes. The dual port rinse station helps minimize analyte carryover and cross contamination.​

Quickly switch samples 

Two discrete liquid flow paths and a dual port rinse station allow the user to switch between oils and coolants testing on demand in as little as 5 minutes. The sliding rinse station controls the two peristaltic pumps. For oils testing, the probe and stirrer are rinsed in ports fed with kerosene or white spirit. For coolants testing, the second peristaltic pump delivers an appropriate rinse agent such as water or nitric acid. By changing the sample probe, stirring paddle and ICP glassware, the analyst can quickly switch from oils testing to coolants testing.​​​

Filtered probe​

​The included stainless steel filtered probe helps filter out large particles, preserving the lifetime of downstream components. The material is ​robust and easy to clean.​

  • Homogenizing Autosamplers

  • Oils 7400 / Oils 7600 Homogenizing Autosampler Installation

​​​Dimensions (H x W x D)
​49 cm x 81cm x 57.5 cm  (19.3" x 31.9" x 22.7")​​​​​​
Weight 35 kg (77 lbs)​
​Capacity
​​​Up to 6 racks, up to 576​ samples​
​Rack options
​Bel-Art, CETAC/Bohdan, Janus
​Hardware interfaces
​RS-232 and USB
​Power requirements
​100-240 VAC, 47-63 Hz, 1.9 A
​Minimum computer requirements
​Microsoft Windows® 10 or later operating system
1 GB RAM
2 COM or USB port
Internet Explorer 6 or higher must be installed
for system to function properly