​Vision AutoPlus Features

  • Precision syringe pump autosampling system 
  • All-inert syringes, valves, tubing, and fluidics 
  • Choice of 6 or 8 sampling syringes (for 6 or 8 vessels) 
  • Volume accuracy and repeatability ±1% 
  • Seamless integration with G2 Classic 6™ and Elite 8™ 
  • Automatic media replace standard with Maximizer™ 
  • Convenient “Auto Start” feature 
  • Automatic addition of dilutions or stabilizers 
  • Optional in-line filter block kit (easy tubing and filter connections) 
  • Handles problem drugs, surfactants, and buffers 
  • Trouble-free maintenance, no peri-pumps or check valves 
  • Small, stacked footprint leaves open bench space in front for waste beaker and other tools​
  • Customizable end of test auto-wash feature automatically prepares the system for the next test 
  • Full color touchscreen with intuitive menus and programming 
  • Up to 100 protocols (create, manage, and save routines) 
  • Upload and download programs with flash drive 
  • Electronics and firmware include 32-bit digital technology 
  • Print to both serial and network (PostScript) printers 
  • Alarms for sampling, maintenance, and calibration 
  • Compatible with non-Hanson dissolution testers 
  • Security: 50 users 
  • 21 CFR Part 11 security compliant 
  • USP / US FDA / ASTM / EP / JP / CE / CSA / RoHS compliant

AutoFill Features

  • ​Precision fraction collector built for the Vision® platform
  • Seamless integration with AutoPlus™
  • Choice of easy install collection racks with rack detection sensors
  • Collect in test tubes for UV or vials for HPLC & UPLC®​
  • Compatible with 13 x 100 and 16 x 100 mm test tubes and 12 x 32 mm vials
  • New wash port with automatic end-of-test wash routine
  • Sample retrieval return to vessel accessory
  • CE / CSA / RoHS compliant, includes earth-friendling packing

Aut​oPlus


​Weight (dry)
​21.3 kg (47.0 lbs.)​
Dimensions (H x W x D)
​46.8 cm (18.4 in.) x 38.1 cm (15.0 in.) x 66.0 cm (26.0 in.)​
Power
​​Input: 24 VDC, 3.75 A, 90 W
Only use external power supply​
​AutoFill​

Weight (dry)
​14.5 kg (32.0 lbs.) ​
Dimensions (H x W x D) ​40.1 cm (15.8 in.) x 28.0 cm (11.0 in.) x 47.3 cm (18.6 in.) ​​
​​​​Sampling​



​Minimum sample interval:
​1 min (5 min is normal) 
​Maximum sample interval: 
​999 hours, 59 min (999:59) 
​Sample time points:
50 max 
​Maximum sample volume:
​90% of vial capacity 
Collection
13 x 100 rack: 18 x 8 test tubes, 144 total
16 x 100 rack: 18 x 8 test tubes, 144 total
12 x 32 rack: 21 x 8 vials, 168 total
UPLC rack (12 x 32): 3 trays 6 x 8 vials, 144 total
Septum: Pre-cut type only. ​
Sampler Volume Accuracy
​0.5 to 5.0 mL: ± 0.05
5.1 to 10.0 mL: ± 0.10
10.1 to 15.0 mL: ± 0.15 ​ ​
Power
Input: 24 VDC, 3.75 A, 90 W
Only use external power supply
External Power Supply 
Input: 100 - 240 V~,50 - 60 Hz, 1.5 A max
Output: 24 VDC, 3.75 A, 90 W ​